SensiFAST SYBR® No-ROX One-Step Kit

Sensitive, reproducible detection of even the most challenging RNA targets, under fast thermal cycling conditions

SensiFAST SYBR® No-ROX One-Step Kit

Sensitive – optimized buffer formulation delivers reliable quantification from even very low copy number RNA targets

Reproducible – consistent results between technical replicates for increased confidence in results

Specific – antibody-mediated hot-start DNA polymerase minimizes non-specific amplification for improved assay sensitivity and reliability

Robust – reliable detection of RNA targets from a broad range of sample types

Fast – delivers reproducible, accurate assay results in as little as 40 minutes

Human ß-actin gene was amplified under fast thermal cycling conditions from a 10-fold serial dilution of RNA using SensiFAST SYBR One-Step Kit (red) and a similar kit from Supplier A (blue). SensiFAST delivers superior sensitivity and reproducibility, across 5 orders of magnitude, as judged by the lower and more consistent Ct values.

Product Description

The SensiFAST™ SYBR® No-ROX One-Step Kit has been optimized for fast, efficient, unbiased cDNA synthesis and subsequent highly-sensitive, reproducible real-time PCR detection in a single tube.

An antibody-mediated hot-start DNA polymerase promotes rapid activation and supports highly-specific amplification, which in turn improves assay sensitivity and dynamic range. A combination of the latest advances in buffer chemistry and PCR enhancers confer superior assay performance under fast thermal cycling conditions. The inclusion of separate RiboSafe Inhibitor ensures accuracy by protecting RNA targets from RNase degradation.

The SensiFAST SYBR® No-ROX One-Step Kit has been validated on all commonly-used real-time instruments that do not require the passive reference dye ROX.

Applications

  • Gene expression analysis
  • Pathogen detection
  • RNA viral pathogen detection
  • Genetic profiling
  • miRNA profiling / quantification
  • Genetically modified organisms (GMO) characterization

Product Specification

Concentration 2x
Presentation BIO-72001: 100 x 20 µL Reactions: 1 x 1 mL
BIO-72005: 500 x 20 µL Reactions: 5 x 1 mL
Appearance Clear, colorless solution
Hot Start Antibody mediated
Application SYBR-based, RT-qPCR
Sample type RNA
Presentation 1 vial / 5 vials
Storage -20 °C, avoid exposure of the SYBR™ to light
Mix stability See outer label
Consistency ±0.5 Ct variance between test and reference sample
DNA Contamination Quantitative PCR analysis with no template. Presence of E. coli and mouse genomic DNA checked. Test sample must amplify in line with control sample.
RNase Contamination No detectable degradation
DNase Contamination No detectable degradation

Product Ordering

Cat. No.              Size

BIO-72001          100 x 20µl Reactions

BIO-72005          500 x 20µl Reactions

Product Support Material

View all Documents

After getting nowhere with other kits we tried the SensiFAST SYBR One-Step Kit and saw res...

Asia-Pacific Special Nutrients Sdn. Bhd.

FAQs:

SensiFAST SYBR® No-ROX One-Step Kit

What is the difference between using ROX and using fluorescein?
Fluorescein is an alternative passive reference dye used just in the Bio-Rad instruments (see Product Selection Tool), the SensiFAST SYBR & Fluorescein contains fluorescein premixed in the mastermix at optimised concentrations.
Is the SYBR in a separate tube?
For your convenience the SensiFAST kits have an optimized amount of SYBR® Green in the mastermix.
Can I use a SensiFAST SYBR Kit for a probe assay?
This is not possible because the SYBR® is pre-mixed into the SensiFAST SYBR® mastermix.
What template (RNA/cDNA) is this compatible with?
SensiFAST One-Step Kits can be used with most RNA/cDNA templates. To give you some idea of a few of the types of templates used with these kits: Human - Rosato R.R., et al. Cancer Res. 67: 9490-500 (2007) Rat - Remund K., et al. Expt. Lung Res. 35: 359-370 (2009) Drosophila - Brown A.E., et al. PloS ONE 4: e4490 (2009) Nitrogen-fixing bacteria - Bahlawane C., et al. Mol. Plant-Microbe Inter. 21: 1498-1509 (2008) Diphtheria bacteria - Jochmann N., et al. Microbiology 155: 1459-1477 (2009) Green algae - Wobbe L., et al. PNAS 106: 13290-13295 (2009) Bovine virus - Park S-I., et al. J. Virol. Methods. 159: 64-6 (2009) For cDNA/DNA templates SensiFAST SYBR® and Probe kits are used. To give you some idea of a few of the types of templates used with these kits: Stem Cell - Bernardo A.S., et al. Stem Cells 27(2): 341 -351 (2008) Cow - Baumert A., et al. J. Dairy Research 76(3): 356-364 (2009) Mouse - Hoyles R.K., et al. Arthritis Rheum. 58(4): 1175-88 (2008) Quail - De Winter P., et al. British Poultry Science 49(5): 566 – 573 (2008) Insect - Bass C., et al. Malaria journal 6 111 (2007) Fish - Miller M.R., et al. J. Nutr. 138(11): 2179-2185 (2008) Crab - Wilcockson D.C. & Webster S.G. Gen. & Comp. Endo. 156: 113–125 (2008) Nematode - Murray S.L., et al. Mol. Plant-Microbe Interactions 20(11): 1431–1438 (2007) Plant - Hecht V., et al. Plant Physiology Preview DOI:10.1104/pp.107.096818 (2007) Yeast - Kawauchi J., et al. Genes & Dev. 22: 1082-1092 (2008) E.coli Bacteria - Saeed H.A., et al. Research J. Microbiology 4(4); 173-177 (2009) Virus - Muscillo M., et al. Water, Air, & Soil Pollution 191: 1-4 (2008)
Can I use a SensiFAST Kit for standard real-time PCR?
Although SensiFAST kits have been designed for fast PCR on the new generation of fast machines, they will work equally well for standard or fast PCR protocols on all real-time PCR machines.
Why do the SensiFAST kits contain a hot-start Taq polymerase?
Polymerase activity during the reaction set-up causes non-specific amplification including primer-dimer formation. To avoid non-specific amplification the polymerase is only activated after heating at 95°C for 2-3 minutes.
I would like to compare SensiFAST with my current qPCR mix. What do I have to consider?
When comparing SensiFAST with a mix from another supplier we strongly recommend to use the suggested conditions for PCR setup and cycling. Every real-time mix has its specific composition and different properties. That’s why they should be tested with their specific conditions, mostly this is possible on different plates only. We recommend amplifying from a ten-fold template dilution series. Loss of detection at low template concentration is the only direct measurement of sensitivity. An early Ct value is not an indication of good sensitivity, but rather an indication of speed.
Why do certain kits contain a ROX?
The emission recorded from ROX during the baseline cycles is used to normalize the emission recorded from the reporter (SYBR®) in later cycles in some instruments. ROX compensates for small fluorescent fluctuations such as bubbles and well-to-well variations that may occur.
Why are the ROX concentrations different?
The amount of the ROX passive reference dye needed varies depending on the instrument optics. Our SensiFAST kits have been optimized for all these different instruments (see Product Selection Tool).
What could be done to avoid unspecific products in melting curve analysis?
Multiple products in melting curve analysis may be caused by unspecific products or primer dimer. However, appearance of multiple bands in melting curve analysis does not necessarily show different products. Multiple peaks may also appear, if distinct regions of the PCR product melt at different temperatures (e.g. due to an inconsistent GC content). We recommend to analyze the PCR product on a gel, to decide if unspecific products are present. The troubleshooting guide of your product insert includes several suggestions to solve these problems. In many cases problems with non-specific products can be solved if the annealing temperature is increased and/or the elongation time is decreased. If you have further questions, please contact Meridian Technical Support.
What is the advantage of working with SYBR Green I?
SYBR® Green I is an inexpensive, universal dye which binds to all dsDNA. It can be easily used in combination with a simple primer pair to detect PCR products in real-time. This dye is very attractive for researchers analysing lots of different genes.
What is the advantage of working with a probe system?
The probe system is always specific, probes only detect the gene of interest. It is also possible to distinguish between similar sequences with small differences like SNPs or mutations. In general, probe assays need less optimization than SYBR® Green I assays.
Why do you not sell kits contain dUTP (and UNG)?
This method is only effective if all the researchers in the laboratory, or using the thermocycler, are all using a dUTP/dNTP and UNG system. If even one researcher is not, it ceases to be an effective control. Using dUTP has also been shown to be inefficient as it increases the Ct values by reducing reaction efficiency. Most labs do not need to use the dUTP method of control, optimised protocols will allow high specificity of PCR and good lab practices (using disposable consumables, the use of filter tips and maintaining a separate area for PCR set-up and PCR amplification and any post-PCR analysis) virtually eliminate the risk of cross contamination.
What is the difference between a one-step and a two-step real-time PCR reaction?
In a one-step reaction the reverse transcription reaction and the real-time PCR reaction are done in one tube, making this a closed tube assay, so contamination can be avoided. It saves pipetting steps and time and is easy in handling, making it ideal for high throughput screening. In a two-step reaction the reverse transcription reaction and the real-time PCR reaction are done in separate tubes. It gives a more flexible way of working in that the cDNA can be used for more than one real-time PCR reaction and can be archived, eliminating the need to continually isolate RNA. For convenience Meridian sells the SensiFAST cDNA Synthesis Kit separately if you wish to take a two-step approach.
What could be the reason of strange shaped qPCR curves? I observed an early increase of the signal and strange shaped qPCR curves without an initial plateau.
A possible reason is that the template amount is too concentrated. An early Ct may impair the baseline correction and may cause these strange curves. We suggest to dilute the template. Alternatively if the curve is flattened, this may be due to inhibitors in the reaction. Running a serial dilution of your sample will dilute the inhibitor concentration, if this corrects the problem, you will either need to go back and re-purify your template, or use it at a lower concentration, where the inhibitor effect has been diluted out.

Get In Touch With A Specialist

Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!

By submitting your information in this form, you agree that your personal information may be stored and processed in any country where we have facilities or service providers, and by using our “Contact Us” page you agree to the transfer of information to countries outside of your country of residence, including to the United States, which may provide for different data protection rules than in your country. The information you submit will be governed by our Privacy Statement.